Setup

Run Your First Desktop CNC G-Code Job in Candle

Run the 3018-PROVer sample engraving in Candle. Preview the G-code, set X, Y and Z work zero, and learn how to stop the machine if needed.

Illustrated title card for the guide: Run Your First Desktop CNC G-Code Job in Candle

To run the 3018-PROVer’s supplied wood engraving, open sainsmart.nc in Candle, check the preview, set X, Y and Z work zero, then click Send. SainSmart engraving instructions

In a typical CNC router programming workflow, this is the stage after CAM generates the toolpaths. Candle sends the toolpath instructions to the router. Candle workflow

Start with an assembled original Genmitsu 3018-PROVer that has passed SainSmart’s pre-run checks, with Candle installed on Windows and the Z probe configured. Pre-run checks · Candle for Windows · Probe setup

Connect and home the router

Unplug the offline controller from the router, open Candle and connect the router to the PC with the supplied USB cable. Check the status in Candle’s device window. 3018-PROVer connection · Candle connection settings

Candle statusWhat to do
Not ConnectedOpen Service → Settings, set the baud rate to 115200, select a COM port and click OK. If the status stays Not Connected, try the next listed port. Connection settings
Port OpenedCheck that the offline controller is unplugged, no other CNC program is connected to the router, and the baud rate is 115200. Connection troubleshooting
Alarm at startupClick the button with a house inside a magnifying glass. The router moves during homing and Candle should show Idle after a successful cycle. Candle homing

Homing finds the machine’s reference position using the limit switches. Grbl v1.1 handles it through the controller command $H. You’ll set the engraving’s work origin on the wood separately. Candle homing · Grbl homing command · Work coordinates

Load and preview the sample

Once Candle shows Idle, choose File → Open and select sainsmart.nc from the microSD card or CD supplied with the router. In the Visualization Pane, look at Work Origin and Work Dimensions. Candle status guide · Sample file and preview

Set the sample’s origin at the bottom-left corner of the wood, on its top surface. The preview gives the following travel from that point. Sample dimensions

AxisTravel from the work origin
X0 mm to the left and 39.812 mm to the right. Sample dimensions
Y0 mm to the front and 10.3 mm to the back. Sample dimensions
Z0.2 mm down, normally the cut depth, and 5 mm up to position the bit. Sample dimensions

Clamp the wood and set work zero

  1. Fit the bit. Fit a supplied engraving bit so its tip can reach at least 0.2 mm below the stock surface. Use one supplied wrench to hold the spindle still and the other to tighten the collet. Bit setup
  2. Clamp the stock. Choose wood with a flat base and top surface and enough room for the full engraving. Clamp it securely to the bed with the clamps clear of the entire toolpath. Stock setup
  3. Zero X and Y. Use Candle’s jog arrows to put the bit directly over the bottom-left corner of the stock. Press the X/Y Origin Control button and check that both X and Y work coordinates read zero. Origin control · Work coordinate check
  4. Position the probe. Raise the bit enough to place the configured probe’s base on the wood beneath it. Attach the alligator clip firmly to the bit where it will stay clear during probing. Probe placement
  5. Set Z zero. Click Z-Probe in Candle to set Z zero at the stock surface. When probing finishes, remove the base and the clip and set them aside. Z zero · Probe removal

Start, monitor and stop the engraving

Check again that the clamps are clear of the entire toolpath before you click Send at the bottom of Candle’s window. The Estimated Time display in the Visualization Pane shows elapsed time and an estimate of total time. Starting the engraving

Stay with the router while it runs. If you need an emergency stop, press the physical emergency stop button on the 3018-PROVer. The spindle should stop and the controller should stop responding to Candle commands until the button is released. Grbl operating caution · 3018-PROVer emergency stop

Evidence and limits. The procedure was documented for the 3018-PROVer with Candle on Windows, with controller terminology from Grbl v1.1. The documentation was checked on November 26, 2026. This guide is not based on hands-on testing. 3018-PROVer instructions · Candle for Windows · Grbl v1.1 reference

Sources

  1. Testing Your 3018-PROVer CNC
  2. How to Install Candle/GRBLControl for Windows 8 or Later
  3. How to Set Up & Use Candle for Multiple Operations
  4. What is a Z Probe & How do I Use it?
  5. Grbl v1.1 Commands

More from the drying rack